Search results for "Axial length"
showing 10 items of 32 documents
What is the influence of parents' myopia on their children's myopic progression? A 22-year follow-up study.
2016
Purpose To study the connection between parental myopia and their children's myopia from school age to adulthood. Methods Two hundred and forty myopic schoolchildren (119 boys, 121 girls, mean age 10.9 years) with no previous spectacles for myopia were recruited to a 3-year treatment trial with different use of spectacles. Follow-ups were performed at mean ages of 13.9, 23.7 and 33.2 years for 238, 176 and 170 subjects respectively. Subjective refraction was calibrated to the spherical equivalent at corneal level (SEcor). Corneal refractive power (CR) and axial length (AL) were measured. Parental myopia was assessed with a questionnaire and the children assigned accordingly to one of three …
Genome-wide association meta-analysis of corneal curvature identifies novel loci and shared genetic influences across axial length and refractive err…
2020
Corneal curvature, a highly heritable trait, is a key clinical endophenotype for myopia - a major cause of visual impairment and blindness in the world. Here we present a trans-ethnic meta-analysis of corneal curvature GWAS in 44,042 individuals of Caucasian and Asian with replication in 88,218 UK Biobank data. We identified 47 loci (of which 26 are novel), with population-specific signals as well as shared signals across ethnicities. Some identified variants showed precise scaling in corneal curvature and eye elongation (i.e. axial length) to maintain eyes in emmetropia (i.e. HDAC11/FBLN2 rs2630445, RBP3 rs11204213); others exhibited association with myopia with little pleiotropic effects …
Anisometropia of ocular refractive and biometric measures among 66- to 79-year-old female twins
2016
Purpose To examine the prevalence of anisometropia of spherical refraction (AnisoSR), astigmatism (AnisoAST) and spherical equivalent (AnisoSE) and their associations with spherical refraction (SR), refractive astigmatism (AST), spherical equivalent (SE) and interocular differences of ocular biometric parameters among elderly female twins. Methods Refraction of 117 monozygotic (MZ) and 116 dizygotic (DZ) female twin subjects aged 66–79 years was assessed with an auto-refractor (Topcon AT) and controlled by subjective refraction. Corneal refraction, anterior chamber depth and axial length were measured with a Zeiss IOL Master. Participants with eyes operated for cataract or glaucoma were exc…
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
2019
ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…
Association of Low Birth Weight With Altered Corneal Geometry and Axial Length in Adulthood in the German Gutenberg Health Study
2019
IMPORTANCE: Low birth weight is associated with altered ocular organ development in childhood, including the morphology of the eye. However, no population-based data exist about this association in adulthood. OBJECTIVE: To evaluate whether low birth weight has a long-term association with anterior segment anatomy and axial length in adulthood. DESIGN, SETTING, AND PARTICIPANTS: The Gutenberg Health Study is a population-based, observational cohort study in Germany. All participants underwent ocular biometry. Among the participants with follow-up and self-reported birth weight available, associations were assessed between low birth weight and anterior segment anatomy and axial length using m…
Nine Loci for Ocular Axial Length Identified through Genome-wide Association Studies, Including Shared Loci with Refractive Error
2013
Refractive errors are common eye disorders of public health importance worldwide. Ocular axial length (AL) is the major determinant of refraction and thus of myopia and hyperopia. We conducted a meta-analysis of genome-wide association studies for AL, combining 12,531 Europeans and 8,216 Asians. We identified eight genome-wide significant loci for AL (RSPO1, C3orf26, LAMA2, GJD2, ZNRF3, CD55, MIP, and ALPPL2) and confirmed one previously reported AL locus (ZC3H11B). Of the nine loci, five (LAMA2, GJD2, CD55, ALPPL2, and ZC3H11B) were associated with refraction in 18 independent cohorts (n = 23,591). Differential gene expression was observed for these loci in minus-lens-induced myopia mouse …
Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients
2011
PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…
The relationship of ocular geometry with refractive error in normal and low birth weight adults
2020
Purpose Low birth weight (BW) individuals have an increased risk for myopic refractive error. However, it is unclear which ocular geometric alterations lead to an increase in myopic refractive error. This study aims to evaluate the impact of ocular biometry in interaction with BW on refractive error. Methods Participants of the prospective, observational, population-based Gutenberg Health Study (GHS) with self-reported BW aged 40–80 years and objective refraction and optical biometry were included. Linear regression analyses were conducted to evaluate associations between spherical equivalent with corneal power, anterior chamber depth, lens thickness and axial length and its interaction wit…
Design and Baseline Characteristics of the HELP Study: An Extended and Long-Term Observation of Pathological Myopia in Caucasians.
2017
<b><i>Purpose:</i></b> To assess the natural disease progression of high myopia in Caucasians considered at risk for the development of myopic choroidal neovascularization (mCNV). <b><i>Methods:</i></b> Subjects were recruited in 25 clinical sites between June 2014 and June 2016. Main inclusion criteria included axial length of ≥26 mm, best-corrected visual acuity ≥0.05 decimal equivalent and presence of at least one out of five predefined morphological disease risk criteria. These were (1) subfoveal choroidal thinning &#x3c; 50 µm, (2) enhanced choroidal curvature length &#x3e; 6,300 µm, (3) lacquer cracks, (4) patchy atrophy &#x3…